MAINTENANCE
Part Action Frequency
Filter Replace filter element. Refer to Page 6 One time per year, or when indicator
on the filter head reaches the end of
the indicator bar.
Automatic drain Clean automatic drain. Refer to Page 6 When required
Replace Filter Element
Turn off the air supply.
Let the system depressurize until the pressure gauge reads 0 psi.
Unscrew the bleed screw (F) slowly to ensure that the filter is depressurized.
Turn the filter bowl (E) counter- clockwise and pull the bowl from the filter housing
(A).
Unscrew the blue knob (D).
Remove the old filter element (C).
Clean the sieve (B) and the filter house, if necessary.
Install a new filter element (C).
Assemble the parts in the reverse order.
Note: A periodic check of the automatic drains is neccesary to ensure the
membrane life. To verify float is functioning correctly, open the filter bowl
by turning one quarter turn counter-clockwise. Inspect for water or oil, an
inactive float will be submerged, an active float will not. If float is found to
be inactive follow cleaning procedure below or if necesary replace with part
number 026-80386-00.
Clean Automatic Drain
Open the filter by turning the bowl one quarter turn counter-clockwise.
Unscrew the nut (F).
Remove the drain unit (B-E) from the filter bowl (A).
Remove the O-ring (E).
Carefully pull the floating house (B) from the seat (D). Do not bend the needle
(C).
Clean the parts with soap and water. Make sure that the needle bore is open
and clean.
Assemble the parts in the opposite direction. Make sure that the parts are dry
before reassembly.
Automatic Pressure Switch Setting
The automatic pressure switch is factory pre-set to shut off shop air consumption at 120 psi. This switch will then
automatically reset when the N
2
Pressure inside the tank drops by approximately 25 psi.
If your application requires an inlet pressure of 100 - 119 psi, an adjustment to the automatic pressure switch is possible.
Please contact RTI Technical Support at 800-468-2321 for further details.